Labelled half section of the test box with an enlarged view of the layer stack at the panel centre
Drawing generated from the build documentation

Problem

Measure how well printed mycelium-mineral panels resist heat flow in place.

What I did

Built an insulated test box with heat-flux sensors and thermocouples, following the ASTM C1046 and C1155 methods, with 24-bit data acquisition on an Arduino and Python analysis. Results are not yet published.

Role

Designed the test box and the measurement: heat-flux sensors and thermocouples with 24-bit acquisition on an Arduino, the logging code, and the test protocol following ASTM C1046 and C1155.

Credits

With I. Datta and E. Baharlou.